AB-Series Specifications

Model AB-120A AB-180A AB-250A AB-350A AB-500A
Grain Column Length 8 FT. 12 FT. 10 FT. 14 FT. 20 FT.
Dimensions          
Transport Length 15' - 2" 19' - 2" 19' - 1.5" 23' - 1.5" 29' - 1.5"
Transport Width 7' - 8" 7' - 8" 8' 8' 8'
Transport Height 10' 10' 13' - 5" 13' - 5" 13' - 5"
Installed Length 13' - 1" 17' - 3" 17' 21' 27'
Installed Width 6' 6' 8' 8' 8'
Installed Height 8' - 8" 8' - 8" 12' - 8" 12' - 8" 12' - 8"
 
Fan(s) 1 1 1 2 2
  28", 1750RPM 28", 1750RPM 36", 1750RPM 28", 1750RPM 36", 1750RPM
  10-13 HP 10-13 HP 10-16 HP 10-13 HP 10-16 HP
 
Heater(s) BTU/HR(MM) 2.3 3 4.6 6 9.2
 
Augers
Top Auger (HP/BPH) 1HP/1500 2HP/1500 3HP/1785 5HP/2090 7.5HP/2500
Bottom Auger (HP/BPH) 1HP/900 2HP/1100 3HP/1900 5HP/2090 7.5HP/2500
 
Metering Roll Drive N/A N/A N/A N/A N/A
 
Electrical Load (MRA) - Excludes auxiliary load and unload equipment amps  
Single Phase 230 Volt 73 94 130 160 200
Three Phase 230 Volt 44 52 76 100 125
Three Phase 460 Volt 22 26 38 50 63
 
Drying Capacity (BPH) - Gross capacity (does not include load and unload times)  
Dry & Cool 25% to 15% 100 150 200 270 390
Dry & Cool 20% to 15% 140 210 260 360 515
Full Heat 25% to 15% 135 200 265 370 530
Full Heat 20% to 15% 190 280 375 520 750
 
Holding Capacity 120 180 250 350 500

Capacities listed are wet bushels, shelled corn at listed input moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain's physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.

Full heat capacities discharge at 17% content resulting in 15% final content after steeping and cooling.