CF/AB-Series Specifications
Models 150-320 | Models 400-600

Model CF/AB-150 CF/AB-190 CF/AB-270 CF/AB-320
Grain Column Length 8 FT. 10 FT. 12 FT. 14 FT.
Dimensions - includes low profile fold up wet bin.
Transport Length 16' - 7" 18' - 7.5" 21' - 2" 23' - 2"
Transport Width 8' 8' 8' 8'
Transport Height 13' - 5" 13' - 5" 13' - 5" 13' - 5"
Installed Length 15' 17' - 6" 20' 21'
Installed Width 8' 8' 8' 8'
Installed Height 14' - 6" 14' - 6" 14' - 6" 14' - 6"
 
Fan(s) 1 1 1 1
  28", 1750RPM 28", 1750RPM 36", 1750RPM 39", 1750RPM
  10-13 HP 10-13 HP 10-16 HP 20 HP
 
Heater(s) BTU/HR(MM) 2.3 3 4.6 6
 
Augers
Top Auger (HP/BPH) 1.5HP/680 2HP/925 2HP/1150 5HP/1800
Bottom Auger (HP/BPH) 1HP/545 1.5HP/680 2HP/815 3HP/955
 
Metering Roll Drive 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR
 
Electrical Load (MRA) - Excludes auxiliary load and unload equipment amps
Single Phase 230 Volt 56 77 96 130
Three Phase 230 Volt 36 44 52 81
Three Phase 460 Volt 18 22 26 41
 
Drying Capacity (BPH)
Dry & Cool 25% to 15% 105 150 205 240
Dry & Cool 20% to 15% 142 202 275 320
Full Heat 25% to 15% 180 240 335 400
Full Heat 20% to 15% 286 375 520 620
 
Holding Capacity (Total) 187 227 325 378
 
Holding Capacity (Column) 150 190 280 326



Model CF/AB-400 CF/AB-460 CF/AB-510 CF/AB-600
Grain Column Length 18 FT. 20 FT. 22 FT. 26 FT.
Dimensions - includes low profile fold up wet bin.
Transport Length 27' - 2" 29' - 2" 31' - 2" 35' - 2"
Transport Width 8' 8' 8' 8'
Transport Height 13' - 5" 13' - 5" 13' - 5" 13' - 5"
Installed Length 25' 27' 29' 33'
Installed Width 8' 8' 8' 8'
Installed Height 14' - 6" 14' - 6" 14' - 6" 14' - 6"
 
Fan(s) 1 1 2 2
  39", 1750RPM 39", 1750RPM 36", 1750RPM 39", 1750RPM
  25 HP 25 HP 15 HP 20 HP
 
Heater(s)        
Top BTU/HR (MM) 7.5 7.5 4.6 6
Bottom BTU/HR (MM) - - 4.6 6
 
Augers
Top Auger (HP/BPH) 5HP/2800 7.5HP/2800 7.5HP/2800 10HP/2800
Bottom Auger (HP/BPH) 3HP/1225 5HP/1360 5HP/1495 7.5HP/1770
 
Metering Roll Drive 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR
 
Electrical Load (MRA) - Excludes auxiliary load and unload equipment amps
Single Phase 230 Volt - - 217 -
Three Phase 230 Volt 95 107 127 166
Three Phase 460 Volt 46 53 63 83
 
Drying Capacity (BPH)
Dry & Cool 25% to 15% 305 330 375 445
Dry & Cool 20% to 15% 415 450 505 605
Full Heat 25% to 15% 505 540 615 745
Full Heat 20% to 15% 865 925 1060 1280
 
Holding Capacity (Total) 509 565 622 735
 
Holding Capacity (Column) 414 460 506 598

Capacities listed are wet bushels, shelled corn at listed input moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain's physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.

Full heat capacities discharge at 17% content resulting in 15% final content after steeping and cooling.