CF-H Series Specifications (go to CMS-H Series specs)

Model CF500H CF750H CF850H CF1000H CF1500H
Grain Column Length 20 FT. 20 FT. 20 FT. 20 FT. 20 FT.
Dimensions - includes low profile fold up wet bin.      
Transport Length 29' - 2" 29' - 2" 29' - 2" 29' - 2" 29' - 2"
Transport Width 8' 8' 8' 8' 8'
Transport Height 12' - 10" 12' - 10" 12' - 10" 12' - 10" 12' - 10"
Installed Length * 27' 29' - 10.5" 29' - 10.5" 29' - 10.5" 29' - 10.5"
Installed Width * 8' 11' - 2" 11' - 2" 11' - 2" 11' - 2"
Installed Height ** 14' - 6" 24' - 5" 24' - 5" 25' - 10" 37' - 2"
*with service platform and buttress system
**above foundation
 
Fan(s) 2 3 3 4 6
  36", 10-16HP 36", 10-16HP 39", 20HP (1) 36", 10-16HP 36", 10-16HP
      36", 10-16HP (2)    
  1750RPM 1750RPM 1750RPM 1750RPM 1750RPM
 
Heater(s) BTU/HR(MM) 9.2 13.8 15.2 18.4 27.6
 
Augers
Top Auger (HP/BPH) 7.5HP/3200 10HP/3200 10HP/3200 10HP/3200 10HP/3200
Bottom Auger (HP/BPH) 5HP/1370 5HP/2140 5HP/2140 7.5HP/2590 7.5HP/2590
 
Metering Roll Drive 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR
 
Electrical Load (MRA) - Excludes auxiliary load and unload equipment amps  
Single Phase 230 Volt 230 325 - - -
Three Phase 230 Volt 120 170 186 216 298
Three Phase 460 Volt 60 85 93 58 149
 
Drying Capacity (BPH)  
Dry & Cool 25% to 15% 265 600 635 800 1095
Dry & Cool 20% to 15% 460 930 1040 1425 1715
Full Heat 25% to 15% 595 941 1068 1190 1785
Full Heat 20% to 15% 1010 1590 1744 2015 3020
 
Holding Capacity (Total) 545 965 1001 1050 1540
 
Holding Capacity (Column) 460 715 826 965 1455

Capacities listed are wet bushels, shelled corn at listed input moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain's physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.

Full heat capacities discharge at 17% content resulting in 15% final content after steeping and cooling.