CF/SA-Series Specifications

Model CF/SA-320 CF/SA-410 CF/SA-510 CF/SA-600
Grain Column Length 14 FT. 18 FT. 22 FT. 26 FT.
Dimensions - includes low profile fold up wet bin.
Transport Length 23' - 2" 27' - 2" 31' - 2" 35' - 2"
Transport Width 8' 8' 8' 8'
Transport Height 13' - 5" 13' - 5" 13' - 5" 13' - 5"
Installed Length 21' 25' 29' 33'
Installed Width 8' 8' 8' 8'
Installed Height 14' - 6" 14' - 6" 14' - 6" 14' - 6"
 
Fan(s)        
Top 28" 28" 36" 39"
  10 HP 1750 RPM 10 HP 1750 RPM 15 HP 1750 RPM 20 HP 1750 RPM
  28" 28" 36" 39"
Bottom 10 HP 1750 RPM 10 HP 1750 RPM 15 HP 1750 RPM 20 HP 1750 RPM
 
Heater(s) BTU/HR(MM)        
Top BTU/HR (MM) 2.5 3 4.6 6
Bottom BTU/HR (MM) 2.5 3 4.6 6
 
Augers
Top Auger (HP/BPH) 5HP/1800 5HP/1800 7.5HP/2800 10HP/2800
Bottom Auger (HP/BPH) 3HP/955 3HP/1225 5HP/1495 7.5HP/1770
 
Metering Roll Drive 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR 1/3HP DC SCR
 
Electrical Load (MRA) - Excludes auxiliary load and unload equipment amps
Single Phase 230 Volt 136 156 217 -
Three Phase 230 Volt 72 92 127 166
Three Phase 460 Volt 36 46 63 83
 
Drying Capacity (BPH)
Dry & Cool 25% to 15% 260 315 395 475
Dry & Cool 20% to 15% 330 450 550 660
Full Heat 25% to 15% 400 470 615 745
Full Heat 20% to 15% 620 815 1060 1280
 
Holding Capacity (Total) 378 509 622 735
 
Holding Capacity (Column) 326 414 506 598

Capacities listed are wet bushels, shelled corn at listed input moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain's physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.

Full heat capacities discharge at 17% content resulting in 15% final content after steeping and cooling.